PVC Valve Nest Polybond Steel Tank Softener
PVC Valve Nest Polybond® Steel Tank water Softener systems with continuous flow rates from 40 gpm to 420 gpm for use in the home, restaurants, hotels and other light commercial uses.
|
Features:
- Single delayed or immediate regeneration
- Hard water bypass during regeneration - optional
- Solid state meter initiated regeneration including rate of flow meter, reset table totalizing meter, self diagnostic status monitoring and remote operating data reporting capability
- Epoxy coated exterior for corrosion resistance
- Self-cleaning, hydraulically balanced positive acting piston control valves
- Timed brine refills (eliminates constant line pressure on shut off float devices)
- Exclusive Polybond® heat fused polyethylene steel lined tanks, epoxy coated exterior for corrosion resistance
- 24 volt operation, easily gasketed twist connect wire connectors(120/60Hz/1pH transformer included)
- PVC Valve nest design - schedule 80PVC
|
|
PVC Valve Nest Softener Specs and Design Data
Single Units - Polybond Steel Tanks
| Model Number |
Grains Capacity(2) |
Recommended Flow Rates |
Mineral Tank Size in.(4) |
Pipe Size in. |
Resin Qty Cu.Ft. |
Max Drain Flow GPM |
Brine Tank Capacity Lbs. |
Space(5) Reqmt LxDxH in. |
| Salt Setting |
Continuous |
Peak(3) |
| 15lb/CF |
10lb/CF |
5lb/CF |
GPM Flow |
PSI Drop |
GPM Flow |
PSI Drop |
| S-152C-PVN |
150,000 |
125,000 |
100,000 |
40 |
9 |
60 |
16 |
18x66 |
2 |
5 |
7 |
700 |
58x24x72 |
| S-182C-PVN |
180,000 |
150,000 |
120,000 |
48 |
14 |
72 |
23 |
18x66 |
2 |
6 |
7 |
700 |
58x24x72 |
| S-212C-PVN |
210,000 |
175,000 |
140,000 |
56 |
8 |
84 |
15 |
24x66 |
2 |
7 |
15 |
1000 |
64x24x72 |
| S-242C-PVN |
240,000 |
200,000 |
160,000 |
64 |
11 |
96 |
20 |
24x66 |
2 |
8 |
15 |
1000 |
64x24x72 |
| S-272C-PVN |
270,000 |
225,000 |
180,000 |
72 |
13 |
108 |
25 |
24x66 |
2 |
9 |
15 |
1000 |
64x24x72 |
| S-302C-PVN |
300,000 |
250,000 |
200,000 |
77 |
15 |
107 |
25 |
24x66 |
2 |
10 |
15 |
1000 |
64x24x72 |
| S-452C-PVN |
450,000 |
375,000 |
300,000 |
87 |
15 |
118 |
25 |
30x66 |
2 |
15 |
20 |
1500 |
70x30x72 |
| S-602C-PVN |
600,000 |
500,000 |
400,000 |
94 |
15 |
125 |
25 |
36x71 |
2 |
20 |
25 |
2500 |
78x39x78 |
| S-902E-PVN |
900,000 |
750,000 |
600,000 |
200 |
15 |
270 |
25 |
42x71 |
3 |
30 |
40 |
2500 |
100x42x78 |
| S-1202E-PVN |
1,200,000 |
1000,000 |
800,000 |
210 |
15 |
280 |
25 |
48x71 |
3 |
40 |
50 |
4500 |
120x52x78 |
Duplex Parallel Units - Polybond Steel Tanks
| Model Number |
Grains Capacity(2) |
Recommended Flow Rates |
Mineral Tank Size in.(4) |
Pipe Size in. |
Resin Qty Cu.Ft. |
Max Drain Flow GPM |
Brine Tank Capacity Lbs. |
Space(5) Reqmt LxDxH in. |
| Salt Setting |
Continuous |
Peak(3) |
| 15lb/CF |
10lb/CF |
5lb/CF |
GPM Flow |
PSI Drop |
GPM Flow |
PSI Drop |
| S-152C-PVN |
300,000 |
250,000 |
200,000 |
80 |
9 |
120 |
16 |
18x66 |
2 |
10 |
7 |
700 |
92x24x72 |
| S-182C-PVN |
360,000 |
300,000 |
240,000 |
96 |
14 |
144 |
23 |
18x66 |
2 |
12 |
7 |
700 |
92x24x72 |
| S-212C-PVN |
420,000 |
350,000 |
280,000 |
112 |
8 |
168 |
15 |
24x66 |
2 |
14 |
15 |
1000 |
104x24x72 |
| S-242C-PVN |
480,000 |
400,000 |
320,000 |
128 |
11 |
192 |
20 |
24x66 |
2 |
16 |
15 |
1000 |
104x24x72 |
| S-272C-PVN |
540,000 |
450,000 |
360,000 |
144 |
13 |
216 |
25 |
24x66 |
2 |
20 |
15 |
1000 |
104x24x72 |
| S-302C-PVN |
600,000 |
500,000 |
400,000 |
154 |
15 |
214 |
25 |
24x66 |
2 |
20 |
15 |
1000 |
104x24x72 |
| S-452C-PVN |
900,000 |
750,000 |
600,000 |
174 |
15 |
236 |
25 |
30x66 |
2 |
30 |
20 |
1500 |
116x30x72 |
| S-602C-PVN |
1,200,000 |
1,00,000 |
800,000 |
188 |
15 |
250 |
25 |
36x71 |
2 |
40 |
25 |
2500 |
130x42x78 |
| S-902E-PVN |
1,800,000 |
1,500,000 |
1,200,000 |
400 |
15 |
540 |
25 |
42x71 |
3 |
60 |
40 |
2500 |
160x42x78 |
| S-1202E-PVN |
2,400,000 |
2,000,000 |
1,600,000 |
420 |
15 |
560 |
25 |
48x71 |
3 |
80 |
50 |
4500 |
186x52x78 |
NOTES:
- Weight and Pressure drop data are estimates.
- Exchange capacity is based upon treating water with 10 gpg total hardness. As CaCo3 at the service rates specified and free of color, odor and turbidity. Capacity is for both tanks.
- Peak flow rates are not recommended for extended periods of time.
- Dimension refers to nominal vessel size only.
- Not including operating and maintenance areas.
- Flow rates reflect both softeners on line providing water.
|