Filters | Softners | R/O | De-Ionizers | Filter Media

E2 Series Reverse Osmosis Machine




Product Information

Operating Pressure: 200-220 psi (14-15 bar)

Nominal Machine Ion Rejection: 95%-98%

Membrane: (3) Osmo®-216-HR(PA)

Membrane Housing: (3) 304 SS, End Entry

Array: 1-1-1 (1 Element per Housing)

High Pressure Pipe Work: 3/8-inch (0.95-cm) Tubing, Nylon

Pump: Brass, Rotary Vane, Positive Displacement

Motor: 3/4 Hp, ODP, 220 VAC, 50 Hz

Control Circuit: 220 VAC, Single Phase

Frame: Painted Carbon Steel, 30-inch (76.20-cm) H x 14-inch (35.56-cm) W x 10-inch (25.40-cm) D

Approximate Weight: 60 lbs (27 kg)

Connections: 3/8-inch (0.95-cm) Inlet, 3/8-inch (0.95-cm) Permeate, 3/8-inch (0.95-cm) Concentrate


Features

Instrumentation / Features:

  • 5-micron pre-filter, 9 7/8-inch (25.08-cm)
  • Flow control center
  • Inlet shut-off valve
  • Thermal protection
  • Concentrate pressure gauge

Deluxe Features:

  • Permeate & concentrate flow meters
  • Stainless steel pump
  • Low inlet pressure switch
  • Conductivity meter

Performance

Permeate Rate:

0.78 gpm

(1125 gpd)

0.18 m³/h

(4.26 m³/d)

50% Recovery

0.78 gpm

(1125 gpd)

0.18 m³/h

(4.26 m³/d)

33% Recovery

Concentrate Rate:

0.78 gpm

(1125 gpd)

0.18 m³/h

(4.26 m³/d)

50% Recovery

1.56 gpm

(2250 gpd)

0.35 m³/h

(8.53 m³/d)

33% Recovery

Recycle Rate:

1.19 gpm

(1417 gpd)

0.27 m³/h

(5.37 m³/d)

50% Recovery

0.41 gpm

(590 gpd)

0.09 m³/h

(2.24 m³/d)

33% Recovery

Feed Rate:

1.56 gpm

(2250 gpd)

0.35 m³/h

(8.53 m³/d)

50% Recovery

2.34 gpm

(3370 gpd)

0.53 m³/h

(12.77 m³/d)

33% Recovery



Back to Top ^